RE: RFID tags

2003-11-20 Thread Rachid Sehb
Some of these passive RFID units are placed on tires , and fall under the automotive directive, so they may as well required RTTE certification. Since this units are capable to radiated energy, they would require to be certified. -Original Message- From: richwo...@tycoint.com [mailto

RE: France's new Frequency allocation

2003-11-03 Thread Rachid Sehb
Cyril, The new publication stated that : indoor use limitation of 100 mW EIRP for the 2.4-2.4835 Ghz band outdoor use limitation of 100 mW EIRP for the 2.4-2.454 Ghz and 10 mW for the 2.454-2.4835Ghz band Find encloses a summary of the frequency allocation for the RLAN and the 5 Ghz. You c

RE: EN 300 328-1

2003-10-06 Thread Rachid Sehb
This is a multi-part message in MIME format. Hello Sam, The diode detector is used to trigger the envelope of the signal. Actually this diode has to be used to determine the power output of the unit since the 802.11(b) would have BW around 10 MHz( the duty cycle would be used to correct the peak

RE: Compliance test configuration

2003-09-03 Thread Rachid Sehb
Ajmani, Yes that is correct, having the unit transmitting information at the highest data rate is the goal. Rachid Sehb EMC engineer < <mailto:rs...@rheintech.com> mailto:rs...@rheintech.com> The information contained in this electronic mail message is privileged and

Defibrillation test

2003-08-18 Thread Rachid Sehb
This is a multi-part message in MIME format. Hello group, I was wondering if someone would know the requirement for shape of the pulse for the defibrillation with stand.This test is described in ANSI/AAMI EC53. Thank you in advance for your comments. Rachid Sehb EMC engineer <>

RE: FCC Human Exposure Limits

2003-08-14 Thread Rachid Sehb
luate compliance with respect to MPE limits based on field strength or power density." The question is would this unit be considered as mobile or portable unit? From: David Seabury [mailto:d.seab...@worldnet.att.net] Sent: Thursday, August 14, 2003 11:55 AM To: Rachid Sehb; richwo...@tycoin

RE: FCC Human Exposure Limits

2003-08-14 Thread Rachid Sehb
Hello Richard, If the device fall into the criteria of " mobile", an RF exposure evaluation would be required. Since you would have two radio collocated, by less than 20cm from each other in the same unit, an MPE evaluation would be required. You would need to show compliance to the whole body ex

RE: Apples and ? comparison of dBuV/m

2003-08-07 Thread Rachid Sehb
transmit at 100 percent duty cycle and with a 50 percent duty cycle. For first configuration we were performing a direct average measurement at the band edge , and for the second configuration we were using the delta marker method. The results were only different by 1 dB. Rachid Sehb Rhein Tech

RE: FCC question

2003-07-30 Thread Rachid Sehb
Dave, I assume that in this utility vault , would be placed other electronic devices, if that the case the unit have to meet the 50 mV/m. Rachid Sehb EMC engineer From: drcuthb...@micron.com [mailto:drcuthb...@micron.com] Sent: Wednesday, July 30, 2003 11:44 AM To: emc-p

RE: CE for components?

2003-06-30 Thread Rachid Sehb
Sam, There is a workgroup working on this concept ( IERSET) to obtain repeatable test in GTEM cell, via simulation by using the IBIS model. So far I don't think they plan to deliver a CE mark for component. May be somebody would have more recent information concerning this subject. http://intra

RE: ATEX Directive

2003-05-19 Thread Rachid Sehb
Good example of the potential impact of a new European Directive is the ATEX Directive (94/9/EC). This Directive replaces the old 'Explosive Atmospheres and Gassy Mines Directive' (76/117/EEC) and is intended to bring products covered by the old directive into line with the other, so called, 'Ne