Re: [PSES] To NRTL or not NRTL, that is the question

2022-09-28 Thread S Drysdale
Avoiding showing bias towards or against any particular NRTL, here is a list of current NRTLs, each with their own specific scope: https://www.osha.gov/nationally-recognized-testing-laboratory-program/current-list-of-nrtls IMHO - it is nobler in the mind to suffer the compliance cost then it is to

[PSES] Question reguarding EN 50131-5-3:2017

2019-10-22 Thread S Drysdale
Hi All, I was hoping someone here could help be better understand EN 51031-5-3 for Alarm systems - Intrusion systems. Section 5.5.4 states: *2) The level of interference generated by the interfering transmitting equipment shall be increased until 2 or more alarm messages out of 5 generated

[PSES] Oct 2nd - TUV SUD Ottawa seminars and open house

2019-09-30 Thread S Drysdale
Dear fellow IEEE EMC-PSTC members, For those able to make it, TUV SUD Ottawa would like to invite you to our open house on the afternoon of Wednesday Oct 2nd, where we are offering multiple free technical seminars. For further details and registration see below: https://www.tuv-sud.ca/ca-en/news-

[PSES] Oct 2nd - TUV SUD Ottawa seminars and open house

2019-09-27 Thread S Drysdale
Dear fellow IEEE EMC-PSTC members, For those able to make it, TUV SUD Ottawa would like to invite you to our open house on the afternoon of Wednesday Oct 2nd, where we are offering multiple free technical seminars For further details and registration see below: https://www.tuv-sud.ca/ca-en/news-a

Re: [PSES] Equipment EMI Issue

2018-09-27 Thread S Drysdale
Hi Robert, Passing the FCC unintentional limits may give reasonable presumption of conformity for non-interference to licensed services requirement, however it does not guarantee such. As others have pointed out, passing this may not be sufficient in itself. However, if the grantee had complaine

Re: [PSES] Taiwan and Korean approvals

2016-08-18 Thread S Drysdale
Hi Peter, Based on your originating IP, I recommend contacting TUV SUD in San Diego. 1 858-678-1400. Chip Fleury would be a good contact normally, but I think he might be on vacation, in which case Vina Kerai is your person. You can tell them Scott Drysdale from Canada sent you their way. Bes

Re: [PSES] Recommendations for DC-DC converter

2016-02-25 Thread S Drysdale
twisted pair power feeds may help and you should > carefully review the mounting of the converter to the platform frame.* > > > > > *Ed Price* > *WB6WSN* > > *Chula Vista, CA USA* > > > > *From:* S Drysdale [mailto:sdd...@gmail.com] > *Sent:* Wednesday, Februar

[PSES] Recommendations for DC-DC converter

2016-02-24 Thread S Drysdale
All, My client has a very tight imposed limit for radiated emissions. Let's assume MIL-STD RE102 army ground. We are exceeding emissions caused by the DC-DC converter. Shielding is difficult in this application, and something we would like to avoid.Space requirements are an issue, and we t

Re: [PSES] Bluetooth audio product

2016-02-12 Thread S Drysdale
I could fully agree about IC (now calling themselves ISED) As IC/ISED typically only accepts data for RF certification up 1 year past measurement date, it is well worth filing for IC/ISED for Canada at the same time as FCC certification. Even if you are not planning on marketing in Canada now, th

[PSES] Indonesia wireless requirements - 902-928 MHz

2015-11-13 Thread S Drysdale
Hi All, I am looking for a reference for the regulations for wireless certifications for a wireless product operating from 902-928 MHz in Indonesia. Output power is about 100 mW, and the product is digitally modulated. Typically it has about 50 channels, but that can be reduced if it needs to be

[PSES] OT - Reference for testing laboratory for IEC 61156-1?

2015-09-22 Thread S Drysdale
Hi All, This is not specifically EMC/Safety related, but many in this group are either test labs or work with various test labs and may be able to help. I was hoping someone could provide a recommendation towards a commercially available 3rd party test lab that performs IEC 61156-1 evaluations, p

[PSES] Nous embauchons (encore)! We're hiring (again)!

2015-07-27 Thread S Drysdale
Hello All, Global EMC Labs, is currently looking to hire a bilingual (English / French) EMC Engineer or Project Specialist. This entry-level hands-on testing role is located in the Montreal (Laval), Canada area. Further details can be found at: http://www.globalemclabs.com/brochures/R-138-Laval

[PSES] Looking for Notified Body for RTTE

2015-05-26 Thread S Drysdale
Hi All, I am looking for recommendations for a Notified Body to contact for a radio transmitting device that does not appear to have a harmonized standard. The frequency range on the device is 9300 to 9500, and the closest standard I can find on the OJ appears to be EN 303 213-6-1.However the devi

[PSES] Vietnam wireless approvals.

2014-09-05 Thread S Drysdale
Dear list members, I was hoping some one might be able to point me in the right direction for Vietnam wireless approvals. The device is already FCC certified under 15.247 and is a 2.4 GHz transmitter. I am trying to find out the requirements for the test lab, the requirements or standards for th

[PSES] DC Magnetic emissions.

2014-05-24 Thread S Drysdale
Good day all, Is anyone here familiar with very sensitive DC magnetic emissions? I am particularly interested in performing measurements in the low mG range, well below the value of the earths magnetic field. I believe a 3 axis helmholtz coil for earth field compensation and a sensitive DC mill

Re: [PSES] Standards for acoustic noise

2014-03-27 Thread S Drysdale
Hi All, I am pulling up an old thread here, because it may relate to my question. Is there any requirement or guidance for sound pressure level limits from ultrasonic equipment operating 40-50 kHz and used in a residential environment? 61010 has a good reference in section 12.5.2, and 60950 has v

Re: [PSES] Canada/IC Import Restrictions Compared to US/FCC

2013-07-11 Thread S Drysdale
Hi Ian, This might be covered under 4(2) of the following http://lois-laws.justice.gc.ca/eng/acts/R-2/page-2.html#h-3 This states "No person shall manufacture, import, distribute, lease, offer for sale or sell any radio apparatus, interference-causing equipment or radio-sensitive equipment for wh

[PSES] Global EMC (Montreal) - Free seminar and open house - June 18

2013-06-13 Thread S Drysdale
Dear Group members, In collaboration with CLD de Laval and Laval Technopole we wish to extend invite to attend our free bilingual seminar. This can be followed by a tour of our facility during our open house. For details see the below:

[PSES] Nous embauchons (encore)! We're hiring (again)!

2012-07-17 Thread S Drysdale