Worldly Experts,

I am having a problem with a product meeting FCC Class A conducted limit at
13.56 MHz due to radiated signal from internal RFID unit coupling into AC
supply conductors.

The host product complies with Class A limits without RFID module
transmitting.  RFID has FCC modular approval, but was compliance tested for
conducted emissions using a dummy load in place of the antenna.  Is it
therefore acceptable to also test host product (for FCC Class A compliance)
with module transmitting into dummy loads instead of actual antenna?

A search of the FCC knowlege database did not turn up any clues.

adTHANKSvance
Bob Sykes
EMC Engineer
        


-



This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. Website: http://www.ieee-pses.org/ 

To post a message to the list, send your e-mail to emc-p...@ieee.org 

Instructions: http://listserv.ieee.org/request/user-guide.html 

List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:

Scott Douglas emcp...@ptcnh.net
Mike Cantwell mcantw...@ieee.org 

For policy questions, send mail to:

Jim Bacher: j.bac...@ieee.org
David Heald: dhe...@gmail.com 

All emc-pstc postings are archived and searchable on the web at:

http://www.ieeecommunities.org/emc-pstc 


Reply via email to