Hi Group,
In EN 55022:2006 section 7.2 there are two options for sample size in
testing. It looks like we can either test with a sample of 5 to 12 units
(7.2.1.1) or we can test just one unit (7.2.1.2). Which is more common
and why would someone choose to test a larger sample over one unit. I
Does anyone know if there are any specifications or standards for
calibrating near field probes?
Thanks,
Cody
-
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
emc-p...@ieee.org
All emc-pstc
Hi all,
I have a question regarding Taiwan regulatory requirements. We have some in
house custom bench top test equipment we have designed and use in our company.
We would like to send a couple units to our plant in Taiwan. Do I need to have
the equipment tested to meet Taiwan regulator
I have a question for the group. I was told that I need matched antennas
to perform a site attenuation measurement. If that is true I would like
to know why. I was planning on using appropriate antennas that cover the
needed ranges, but they are not identical.
Thanks,
Cody
-
This message is
Hi all,
We are in the process of building an OATS and we have a building/enclosure
that is made of fiberglass. A link to the enclosure link can be seen below. My
question is does the door opening to the dome need to be facing the antenna
mast while tests are running so that there is no
Hi all,
How and what do United States labs typically do (use) to power EUTs that run
at 110V 60 HZ and at 220V 50Hz. Also are there other power voltage/frequency
combinations I should be considering besides those two mentioned.
Thanks,
Cody Miller
-
I am in the market for an antenna mast. Does anyone know of a used antenna
mast for sale?
Please respond directly to me.
Thanks,
Cody
- This
message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list.