Or maybe they meant "2kV Line + Line". This is usually a common mode test.
The Other Brian
From: Amund Westin [mailto:am...@westin-emission.no]
Sent: Friday, February 12, 2016 9:33 AM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: [PSES] Burst testing - Line-to-Line??
IEC60092-504 &l
IEC60092-504 < Electrical installations in ships - Part 504: Special
features - Control and instrumentation>
On burst test, they refer procedure IEC61000-4-4.
But in addition, they say: 2kV line/line on power supply port.
So far, I have only seen Line/line testing during surge test.
I suspe