RE: EN50024

2001-11-30 Thread Gary McInturff
, operator response is permitted to re-initialize an operations. Gary -Original Message- From: Yow, Steve (IndSys, GEFanuc, NA) [mailto:steve@gefanuc.com] Sent: Friday, November 30, 2001 7:30 AM To: 'EMC Post' Subject: EN50024 I know the answer is "go buy the dar

RE: EN50024

2001-11-30 Thread Bailey, Jeff
EMC Post' Subject: EN50024 I know the answer is "go buy the darn standard", I thought I had it, but cant seem to find it. I have a simple question though and I know someone has the answer. In EN50024 what is the requirement for ESD. Is it 4kV contact and 8 kV air, Criterion

EN50024

2001-11-30 Thread Yow, Steve (IndSys, GEFanuc, NA)
I know the answer is "go buy the darn standard", I thought I had it, but cant seem to find it. I have a simple question though and I know someone has the answer. In EN50024 what is the requirement for ESD. Is it 4kV contact and 8 kV air, Criterion B??? Regards, Stephen Yow