RE: EN55022:1995 vs EN55022:1998

2000-05-24 Thread Joshua Wiseman
not required to do so in the immunity portion of testing. My two cents... Josh -Original Message- From: Binnom, Cyril A [mailto:binno...@ems-t.com] Sent: Wednesday, May 24, 2000 11:49 AM To: emc-pstc Subject: EN55022:1995 vs EN55022:1998 Group, I have some questions regarding EN 55022

EN55022:1995 vs EN55022:1998

2000-05-24 Thread Binnom, Cyril A
Group, I have some questions regarding EN 55022:1998. 1) Judging by what I have read it would seem that if your products are without telecommunication ports then you are already compliant to EN 55022:1998 since all changes to the new standard are telecommunication product based. 2) If