29, 2010 5:59 AM To: Tony T; EMC-PSTC@LISTSERV.IEEE.ORG Subject: RE: Radiated Emissions Detector Rationale of EN 301 489 Not only this standard uses peak AND average detectors above 1 Gig. Most do or will. The newest version of EN 55022 will also use both detectors. The QP detector

RE: Radiated Emissions Detector Rationale of EN 301 489

2010-09-29 Thread emc-p...@ieee.org
g.grem...@cetest.nl Subject: RE: Radiated Emissions Detector Rationale of EN 301 489 To: Tony T ton...@europe.com, EMC-PSTC@LISTSERV.IEEE.ORG Date: Wednesday, September 29, 2010, 8:59 AM Not only this standard uses peak AND average detectors

RE: Radiated Emissions Detector Rationale of EN 301 489

2010-09-29 Thread emc-p...@ieee.org
Not only this standard uses peak AND average detectors above 1 Gig. Most do or will. The newest version of EN 55022 will also use both detectors. The QP detector is not so suitable for measuring potential interference levels. It was meant for AM broadcast signals being interfered.