Barry
You can also look at the UL Standard for Vacuum cleaning machines (UL1017).
The dielectric test on "powered" vacuum hoses also employed lead shot.
Kelly
At 10:03 AM 3/17/00 +0200, Peter Merguerian wrote:
>
>Barry,
>
>In my old days working for UL, we used lead shot to test the dielectr
Hello Barry,
you might check IEC 60851-5 (Test methods for winding wires) where Clause
4, (Test 13) uses the metal shot when determining breakdown voltages of a
twisted winding wire.
This test is also referenced in IEC 60950 Annex U.2.1.
mit freundlichen Gruessen/ best regards
Volker Gasse
IB
Barry,
In my old days working for UL, we used lead shot to test the dielectric
strength properties of insulated wire connectors. I suggest you take a look
at the wire connector standards UL486 Series.
At 15:26 16/03/2000 -0600, barrym wrote:
>
>I'm looking for reference to any standard which m
I'm looking for reference to any standard which may provide specifics for
using lead shot for dielectric strength testing. I know this done for
insulation system qualifications, just have not identified a standard for
the test set up.
Thanks,
Barry Marks
---