I got it!
thanks a lot guys.
I just realized I had to change polarity of OUTPUT SCALE and INPUT SCALE.
thanks again!
-pat
On Thu, Nov 26, 2009 at 6:17 AM, John Thornton wrote:
> In the Hal/Basic Configuration section of the Integrators Manual
>
> Changing the polarity of a signal
>
> If exter
In the Hal/Basic Configuration section of the Integrators Manual
Changing the polarity of a signal
If external hardware expects an ``active low'' signal, set the corresponding
-invert
parameter. For instance, to invert the spindle control signal:
setp parport.0.pin-09-invert TRUE
John
O
Don't blame me, my machine works. ;)
2009/11/25 Ian W. Wright
> Sven,
>
> Put OUTPUT_SCALE back to where it was and try putting a
> minus in front of INPUT_SCALE
>
> Ian
>
>
--
Let Crystal Reports handle the reporting -
Sven,
Put OUTPUT_SCALE back to where it was and try putting a
minus in front of INPUT_SCALE
Ian
--
Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day
trial. Simplify your report design, integra
2009/11/25 Pat Lyons
> I got my mill working yesterday only to find out that the x-axis is
> backwards and mills mirror images of what I intended.
>
> I tried flipping "OUTPUT SCALE" 's polarity but it didnt seem to do
> anything
> at all... I went looking for some other ini or hal file change t
I got my mill working yesterday only to find out that the x-axis is
backwards and mills mirror images of what I intended.
I tried flipping "OUTPUT SCALE" 's polarity but it didnt seem to do anything
at all... I went looking for some other ini or hal file change to make and
couldnt find any.
Any