David Weinshenker wrote:
> 
> John Carmack wrote:
> >
> > At 01:49 PM 2/28/2003 -0800, you wrote:
> > >  Yup , another thing to think about is if you have a lot of nozzles in your
> > >100 ratio plug , after 50,000 ft you shut off 1/2 of them , Instant 200
> > >ratio ! ( Isp 300 to 340 )
> >
> > I don't think you get to 340 with even an infinite expansion in vacuum.
> 
> Well, using isp.exe, the available specific impulse with
> 100%HTP / RP1 (o/f ratio 7.0:1 appears to be close to optimum)
> is as follows, for various chamber/exit combinations:
> 
> 400/14.7   252
> 400/10.0   263
> 400/4.0    286
> 400/0.5    323
> 
> -dave w

Oops - forgot to add that "chamber/exit combinations" are in psia.

-dw