[etherlab-users] Syncing master to the reference slave: should I care?

2018-11-17 Thread Mohsen Alizadeh Noghani
Hello everyone. In terms of choosing the reference clock in the network, there are two options. In the first method, PC clock is chosen as the reference and in the second one, slave 0's clock is the reference. 1- Syncing slave 0's clock to the master (application) time: this is the method used by d

[etherlab-users] Regular "working counter changes" error

2018-11-17 Thread law_...@aliyun.com
Dear all, I am running Etherlab master with Gavin's patches to drive some IO modules and servo drivers. All the slaves are successfully configured and switched to OP. But I got a lot of working counter warnings begin from it is started. Part of the dmesg log is shown below: [ 4764.4206