Hi Sean,

One of our developers created a code example to do APM between ports on an
HCA. This code is available in Section 8.1 of the Mellanox RDMA Aware
Programming User Manual which is available here:

http://www.mellanox.com/related-docs/prod_software/RDMA_Aware_Programming_us
er_manual.pdf

Thanks

Rupert

-----Original Message-----
From: ewg-boun...@lists.openfabrics.org
[mailto:ewg-boun...@lists.openfabrics.org] On Behalf Of Hefty, Sean
Sent: Thursday, May 02, 2013 5:28 PM
To: Sean T Price; ewg@lists.openfabrics.org
Cc: Prescott Turner
Subject: Re: [ewg] Automated Port Migration on RC connected QPs

> Does anyone have example code on how to setup automatic port migration 
> correctly for RC connected QPs that use RDMA CM?

The RDMA CM does not support APM.  You could use the RDMA CM to connect, but
would need to exchange alternate path information in band and modify the QP
directly to set the alternate path information and APM state.

- Sean