On Tue, Aug 18, 2015 at 07:04:21PM +, Timothy Gu wrote:
> On Tue, Aug 18, 2015 at 9:01 AM Stephen Hutchinson wrote:
>
> > When building SDL with MinGW, it sets -mwindows with the
> > assumption that the application is a GUI application. If this
> > is linked without passing -mconsole to confi
On Tue, Aug 18, 2015 at 9:01 AM Stephen Hutchinson wrote:
> When building SDL with MinGW, it sets -mwindows with the
> assumption that the application is a GUI application. If this
> is linked without passing -mconsole to configure via
> --extra-ldflags, stdout will be silenced from cmd.exe while
When building SDL with MinGW, it sets -mwindows with the
assumption that the application is a GUI application. If this
is linked without passing -mconsole to configure via
--extra-ldflags, stdout will be silenced from cmd.exe while
running FFmpeg.
The -mwindows flag that causes this behavior is i