. It's not perfect, but it's the best. Howard Subject: [Flexradio] SGC-500 From: harryh...@aol.com Date: Sat, 13 Mar 2010 12:09:23 EST To: flexradio@flex-radio.biz To: flexradio@flex-radio.biz Howard: I am curious why

[Flexradio] SGC-500

2010-03-13 Thread Harryhahn
Howard: I am curious why you need to switch your SGC for bands when it is an automatic function of the SGC-500. I own two of them and they work fine without external band switching. I do use external switching to reset the SGC if it senses a bad SWR, etc condition, plus I do remote switch AC

[Flexradio] SGC-500

2008-08-03 Thread Harry Hahn
I use an SGC 500 as one of my amps, driven by the 5000. With 30 watts in you should have full output. Your problem when you trip the curent protection is actually low voltage. You have to read peak voltage across the power in terminals of the amp. I placed a 1 ferad capacitor that has a digital

Re: [Flexradio] SGC-500

2008-08-03 Thread K6JEK
Actually, the CURR trip can be caused by a variety of conditions. Low voltage is certainly one of them. I have gone 9 rounds with CURR tripping on my multiple SGC 500's (I have three now). Things that I've found will make the CURR fault occur: 1) Low voltage. There is a LOW VOLTAGE