Exactly the same findings here Ed,
Any digital or prolonged SSB pushed the heat up rapidly and the Silenx fans
were unable to regulate it.
Actually the original fans are incorrectly rated... my tests show that they are
closer to 34CFM using an airflow meter.
I’ve no idea what the dBA actually
From:Ed Wilson [mailto:ed.wil...@ymail.com]
Sent: 15 January 2013 22:04
To: Ray percival; flexradio@flex-radio.biz
Subject: Re: [Flexradio] Silenx fan Mod on Flex 3000- beware
Colleagues,
I
was one of those guys who just could not stand the noise of the
original Flex-3000 fans, so I ins
Exactly the same findings here Ed,
Any digital or prolonged SSB pushed the heat up rapidly and the Silenx fans
were unable to regulate it.
Actually the original fans are incorrectly rated... my tests show that they
are closer to 34CFM using an airflow meter.
I've no idea what the dBA actua
Part 2...
For the heck of it Ive ordered an audio level meter so Ill be able to make
some actual readings of audio levels when it arrives, probably next week.
I ended up using ThermaTake DuraMax6 fans myself, these are rated at 30CFM
and 32dBA this cut the noise down a fair bit but not as
Further testing results...
Out of the box Duramax 6 fans are 28CFM and 160mA @12v
Modified Duramax6 with resistor are 22CFM and 110mA @12v
Key down continuous CW testing at 10W reaches 82 Degrees C after about 10
minutes with modified Duramax 6 fans.
So I think the standard ThermalTake
What should be the stanfard temp
I have mine installed the s?ilentex and do dee they are not as good as stock
but I have not had the red warning come on
Sent from my personalized C Spire Wireless Galaxy S IIIRay percival
wrote:Further testing results...
Out of the box Duramax 6 fans are 2
@gmail.com; flexradio@flex-radio.biz
Sent: Wednesday, January 16, 2013 4:56 PM
Subject: Re: [Flexradio] Silenx fan Mod on Flex 3000- beware
What should be the stanfard temp
I have mine installed the s?ilentex and do dee they are not as good as stock
but I have not had the red warning come on
Sent
Interesting info Ed, I'll have to test my fans a bit more and perhaps tweek the
resistors to keep the temp below 80.
Heres my 2c...
Ultimately the original fans have a very high output (38 cubic feet per min) at
12v (and probably even more at 13.8v). This is probably to allow for the worst
set