Re: Module counter reset option

2003-06-20 Thread Kostas Kalevras
On Wed, 18 Jun 2003, Roberto Pioli wrote: > I read in the radiusd.conf that the reset option fo the counter module can > be user define. > How can I do this? # It can also be user defined. It should be of the form: # num[hdwm] where: # h: hours, d: days, w: weeks, m: mo

Module counter reset option

2003-06-18 Thread Roberto Pioli
I read in the radiusd.conf that the reset option fo the counter module can be user define. How can I do this? Thanks Rob - List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html

Re: counter reset

2002-12-19 Thread Kostas Kalevras
On Wed, 18 Dec 2002, Remus Anca wrote: > > > Hi, > > i've succesfull use freeradius 0.8 with counter module, and > reset=never, but after some weeks, my server was restarted, and i've > see that the counter was reinitiated with 0 for all users. > > Than, i've tested my self, and after i make a f

counter reset

2002-12-18 Thread Remus Anca
Hi, i've succesfull use freeradius 0.8 with counter module, and reset=never, but after some weeks, my server was restarted, and i've see that the counter was reinitiated with 0 for all users. Than, i've tested my self, and after i make a freeradius stop and start, the counter was reset again.