change either the symbol or the footprint to match.
Wouldn't it also be possible to use gsch2pcb and then run the script
file it generates? If I understand its function correctly it renames
the pads of the footprints.
___
geda-user mailing list
Wouldn't it also be possible to use gsch2pcb and then run the script
file it generates? If I understand its function correctly it renames
the pads of the footprints.
Renames, not renumbers. A name is something like P1.5/INTB/TXD or
\_RESET\_- i.e. the symbolic name or label associated with
I have attached the symbol and footprint files for a laser diode. Can
someone please take a look and see why I'm getting these errors. I
checked the symbol in gsymcheck and it passes with no errors.
Thanks
On Fri, Oct 3, 2008 at 2:12 PM, Rob Butts [EMAIL PROTECTED]
wrote:
the pins are named PD+ and the like in the foot print
the pins are numbered 1 2 3. and the like in the symbol
so the net list is looking for pins named 1 2 3
but the footprint is named PD+ PD-
change either the symbol or the footprint to match.
i used the quotes on numbered