My proposal to solve the problem (and also the problem of hidden power
connections):
1) rename all net=xxx attributes in all symbols with power=xxx,
2) have a little tool in gschem that can do
a) add an external net=yyy attribute that connects (for example) pin 14 of
U1 (which is 7400) to a
Having multiple netnames should not be a problem and work sometimes.
Methinks that having multiple netnames for the same net should ALWAYS
trigger a DRC error.
For connecting different nets there must be a schematic which connects
the nets. Why should manual connecting nets be an
Hi all,
I have a terrible problem which I could not solve :-(
I have a set of circuits drawn with gschem.
I use gsch2pcb to make the netlist and use it in pcb
I allways get the following message:
WARNING: Trying to rename something twice:
PLUS5V and PLUS5V
are both a src and dest name
Levente schrieb:
Klaus Rudolph [EMAIL PROTECTED] wrote:
Hi all,
I have a terrible problem which I could not solve :-(
I have a set of circuits drawn with gschem.
I use gsch2pcb to make the netlist and use it in pcb
I allways get the following message:
WARNING: Trying to rename something
On Thursday 20 December 2007 11:48:40 Klaus Rudolph wrote:
Levente schrieb:
Could you upload somewhere, and send the link?
Sorry, I have no web space :-(
http://www.rapidshare.com/
Peter
--
Peter Brett
Electronic Systems Engineer
Integral Informatics Ltd
Klaus Rudolph [EMAIL PROTECTED] wrote:
Levente schrieb:
Klaus Rudolph [EMAIL PROTECTED] wrote:
Hi all,
I have a terrible problem which I could not solve :-(
I have a set of circuits drawn with gschem.
I use gsch2pcb to make the netlist and use it in pcb
I allways get the following
I have three nets which use different names but should connected. This
is Vcc because this is used in an avr symbol, then I use +5V from an
other symbol (power) and then I have a net called PLUS5V. In one
That is the problem. Make your symbols netname free. One net should have
Well hierarchicaly I use presidence to determine the netname. The
netname is set from the top out.
So no having multiple netnames for the same net shouldn't always trigger
a drc error.
There should be a rule for which name to use under certain
circumstances.
One case where I used multiple net
On Dec 20, 2007, at 2:47 PM, Steve Meier wrote:
On Thu, 2007-12-20 at 14:44 -0700, Andy Peters wrote:
On Dec 20, 2007, at 5:47 AM, Klaus Rudolph wrote:
Having multiple netnames should not be a problem and work
sometimes.
Methinks that having multiple netnames for the same net should
On Dec 20, 2007, at 2:47 PM, Steve Meier wrote:
Well hierarchicaly I use presidence to determine the netname. The
netname is set from the top out.
So no having multiple netnames for the same net shouldn't always
trigger
a drc error.
I have a recent board that needed just one part from
10 matches