Hi Miral,
Please see inline.
Cheers,
Med
> -Message d'origine-
> De : Meral Shirazipour [mailto:meral.shirazip...@ericsson.com]
> Envoyé : mardi 13 octobre 2015 18:31
> À : BOUCADAIR Mohamed IMT/OLN
> Cc : draft-ietf-pcp-port-set@tools.ietf.org; gen-art@ietf.org
> Objet : RE: Gen-ART
Hi Simon,
Thank you for the reply. Please also see the exchange with Mohamed on this
thread.
I agree that the client may not know in advance, but I think what happens to
the unused ports (i.e. when are they released?) is worth mentioning. A
heuristic, guidance etc. would be useful. Also what-
Hi,
Many thanks for the clarifications. Please see inline.
Best,
Meral
> -Original Message-
> From: mohamed.boucad...@orange.com
> [mailto:mohamed.boucad...@orange.com]
> Sent: Tuesday, October 13, 2015 4:42 AM
> To: Meral Shirazipour; draft-ietf-pcp-port-set@tools.ietf.org; gen-
>
Le 2015-10-12 01:49, Meral Shirazipour a écrit :
> Minor issues:
> -[Page 7], Section 4.1, "If the PCP Client does not know the exact number of
> ports its requires, it MAY then set the Port Set Size to 0x, indicating
> that it is willing to accept as many ports as the PCP server can offer."
Dear Meral,
Many thanks for the review.
Please see inline.
Cheers,
Med
> -Message d'origine-
> De : Meral Shirazipour [mailto:meral.shirazip...@ericsson.com]
> Envoyé : lundi 12 octobre 2015 07:49
> À : draft-ietf-pcp-port-set@tools.ietf.org; gen-art@ietf.org
> Objet : Gen-ART Last