Yang Ye wrote:
Hi, Saf
We use a special bond for heme, specified in specbond.dat. Check the
mailing list archive.
Or http://wiki.gromacs.org/index.php/specbond.dat
Mark
___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mail
Shahrokh Safarian wrote:
Dear colleagues
As you know if we want to introduce a new molecule into Gromacs, the
related parameters for that molecule (e.g. [atoms], [bonds], [pairs],
[dihedrals] and so on) should be inserted to the Gromacs rtp file.
Strictly, no. Only if you want pdb2gmx to recog
abhigna polavarapu wrote:
Hi Mark,
I need to calculate the individual energies of aminoacids
using Gromacs. But while using energygrps option in .mdp file for each
amino acid I can only calculated the nonbonded energies of this residue.
Is there a way where I can calculated th
OZGE ENGIN wrote:
Hi all,
My peptide contains two adversely charged residues. I use PME option for the
investigation of electrostatic interactions within my system. The total charge
of the box must be neutral. Since the system contains adversely charged
residues, is it still necessary to add
You may try NOC, downloading at http://noch.sourceforge.net
It can do residue by residue mutation in GUI.
___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.grom
I've coded a model for real time structure alignment in NOC
http://noch.sourceforge.net
It's easy to adapt the code to fit your need.
___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the
Thanks Yang Ye! I will look into this further. Thanks for the program, I'm
sure that will save me much time.
Russell Green
On 6/11/07, Yang Ye <[EMAIL PROTECTED]> wrote:
As what we normally do with dPCA, after obtaining the 2D projection of
first and second principle, we make it into a 3D pl
Yang Ye wrote:
As what we normally do with dPCA, after obtaining the 2D projection of
first and second principle, we make it into a 3D plot of free energy
surface. The awk program is provided below to do such conversion. On
this surface, we can located regions with low free energy and this lead
As what we normally do with dPCA, after obtaining the 2D projection of first
and second principle, we make it into a 3D plot of free energy surface. The awk
program is provided below to do such conversion. On this surface, we can
located regions with low free energy and this leads us to go back
Hi,
First, our simulation system in physical world are mostly neutralized instead
of carrying charges. Second, there is requirement for PME for electrostatic
calculations. Neutralization is a not a must in 3.3.1 Gromacs; a background
charge will complement for the charges that system carries, b
-dropunder
-dropover
- Original Message
From: "[EMAIL PROTECTED]" <[EMAIL PROTECTED]>
To: gmx-users@gromacs.org
Sent: Tuesday, June 12, 2007 1:57:25 AM
Subject: [gmx-users] trjconv -drop drop.xvg ??
Dear community,
Could anybody help me out with the -drop option of trjconv? I would like
Dear Gromacs community,
I've been using the PCA analysis in dihedral space for a chain of my
protein of interest. I made a script to collect the atom quadruplets
corresponding to the phi and psi angles and output them to an index file. I
followed the steps in the paper manual and everything w
Dear community,
Could anybody help me out with the -drop option of trjconv? I would like to have
trjconv re-write an xtc trajectory dropping frames of given time values that I
inserted into a file called "drop.xvg". This file looks like:
1
4.5
etc.
(one single column with times (ps) of the frame
Elias santos wrote:
Hi!!
I want know because we must neutralize the total load of the system
(protein + water) into of the box with genion.
You should neutralize the system and you also may want to add extra ions
to get up to physiological salt concentration.
--
Hi!!
I want know because we must neutralize the total load of the system (protein
+ water) into of the box with genion.
___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at htt
Hi there,
I know this is not related to GMX but was wondering if you could kindly help me
out to find a program for flexible alignment of molecules. I know GASP from
Tripos but will appreciate it if you could introduce to me others programs
available out there either commercial or freewares.
B
Hi there,
I have a complex protein-peptide in a box 6.5 6.5 6.5 with a starting periodic
image of 3.0 nm,
using PME and rlist=rvdw=rcoulomb=0.9.
Now, I use to check the pi dist during my simulation in order to make sure that
the box is larger
enough. After 6ns I get this result:
0
Dear David and Stephan,
Thank you for your suggestion
and I will go through it. If i will get any problem, I
contact you.
with regards,
Ngaraju Mulpuri.
yes, tpbconv has been given the energy file. gmxcheck says trr and edr files
look happy, the original .tpr looks fine from gmxdump and doesn't crash when
it's rerun, and any output from tpbconv looks fine from scanning bits of it in
text format, though it's a pretty massive file and I've no ide
19 matches