Dear Erik,

Thank you so much for your prompt reply. I appreciate it.

Yun-an Yan

Erik Marklund writes:

>For more exotic NVE-systems I had to do some or several of the following

>things to get stable Etot:

>* have an even shorter timestep than one would expect from the applied
>constraints and such.

I will try a timestep with 0.5 fs.
>* use double precision.
The double precision is already in use.
>* apply the constraints with lower tolerance/more iterations etc.
I thought shake_tol = 1.e-8 is small enough. May I try an even smaller value? Or the lincs algorithm with lincs_order=8 and lincs_iter=2 is recommended
instead of shake?
>Then there's a few things I notice in your setup:
>* I see that you do not use constrints at all. I would give it a shot.
I will try.

>* Why do you have two separate comm-grps?
Since it is a solute-solvent fashion MD, I am trying to keeping the solute part close the center of the simulation box. But it does not work in this way.
Do you have any idea about that?

>Erik Marklund
>
>--
>-----------------------------------------------
>Erik Marklund, PhD student
>Dept. of Cell and Molecular Biology, Uppsala University.
>Husargatan 3, Box 596,    75124 Uppsala, Sweden
>phone:    +46 18 471 4537        fax: +46 18 511 755
>erikm at xray.bmc.uu.se    http://folding.bmc.uu.se/
-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to