[gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-12-14 Thread benjfitz
Looks like it is not an issue in the mpi version, but the normally-threaded gromacs-4.6 beta2 version dies at 1.07 us as well. -- View this message in context: http://gromacs.5086.n6.nabble.com/PARTIALLY-SOLVED-Diatomic-in-MeCN-NPT-NH-and-PR-simulation-segfaults-after-1-us-tp5001845p5003771.htm

[gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-12-08 Thread benjfitz
This is fixed in 4.6-beta1, though I am using the mpi version instead of the single-node threaded version. -- View this message in context: http://gromacs.5086.n6.nabble.com/Diatomic-in-MeCN-NPT-NH-and-PR-simulation-segfaults-after-1-us-tp5001845p5003594.html Sent from the GROMACS Users Forum m

Re: [gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-11-13 Thread Justin Lemkul
On 11/13/12 2:56 PM, benjfitz wrote: Are there any other tests I should run to diagnose the problem? I doubt there's anything that can be done that will be particularly useful. You could compile in debugging mode and try to do a backtrace when the problem occurs, but if you have a means t

[gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-11-13 Thread benjfitz
Are there any other tests I should run to diagnose the problem? -- View this message in context: http://gromacs.5086.n6.nabble.com/Diatomic-in-MeCN-NPT-NH-and-PR-simulation-segfaults-after-1-us-tp5001845p5002927.html Sent from the GROMACS Users Forum mailing list archive at Nabble.com. -- gmx-

[gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-11-10 Thread benjfitz
Justin, The main result is that extending the run in 500 ns chunks, per your suggestion, appears to bypass this error. I used the first method listed on the gromacs page for extending runs. tpbconv -s cs2-npt-1us-b.tpr -extend 50 -o cs2-npt-1pt5us-c.tpr mdrun -s cs2-npt-1pt5us-c.tpr -cpi cs2-

Re: [gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-11-06 Thread Justin Lemkul
On 11/6/12 9:01 AM, benjfitz wrote: Thanks for the suggestion, I should have mentioned Tcoupl and Pcoupl in my previous post. I changed them from Nose-Hoover/Parrinello-Rahman to V-rescale/Berendsen and one permutation mixing the two, but it crashed all the same. The nodes have at least 8 GB o

[gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-11-06 Thread benjfitz
Thanks for the suggestion, I should have mentioned Tcoupl and Pcoupl in my previous post. I changed them from Nose-Hoover/Parrinello-Rahman to V-rescale/Berendsen and one permutation mixing the two, but it crashed all the same. The nodes have at least 8 GB of ram and free -m shows that I'm not run

Re: [gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-11-06 Thread Justin Lemkul
On 11/5/12 11:25 PM, benjfitz wrote: Justin, thank you for reminding me that I need to adhere to sane parameters. I do have a few clarifying points, as it were. I tried these simulations again, but with a larger box and 0.9 nm cutoffs, and received a segfault at the same simulation time. The m

[gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-11-05 Thread benjfitz
Justin, thank you for reminding me that I need to adhere to sane parameters. I do have a few clarifying points, as it were. I tried these simulations again, but with a larger box and 0.9 nm cutoffs, and received a segfault at the same simulation time. The model I am using, from the user contribute

Re: [gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-10-15 Thread Justin Lemkul
On 10/15/12 11:45 AM, benjfitz wrote: As a further check I ran a neat solvent box and the simulation ends abruptly at 1.07 us. These results suggest that your physical model is unstable. A linear model of a triatomic species is not stable. A more appropriate approach is to use virtual s

[gmx-users] Re: Diatomic in MeCN NPT (NH and PR) simulation segfaults after 1 us

2012-10-15 Thread benjfitz
As a further check I ran a neat solvent box and the simulation ends abruptly at 1.07 us. -- View this message in context: http://gromacs.5086.n6.nabble.com/Diatomic-in-MeCN-NPT-NH-and-PR-simulation-segfaults-after-1-us-tp5001845p5002046.html Sent from the GROMACS Users Forum mailing list archi