Re: [gmx-users] User-define non bonded table

2013-06-07 Thread Justin Lemkul
On 6/7/13 10:33 AM, Steven Neumann wrote: It is stated in manual that tables must always contain 7 columns with a meaningful data (i.e. no zeros). must be entered in all columns. That may be an erroneous statement. Within very short distances, you will have nearly infinite forces, so zeroes

Re: [gmx-users] User-define non bonded table

2013-06-07 Thread Steven Neumann
It is stated in manual that tables must always contain 7 columns with a meaningful data (i.e. no zeros). must be entered in all columns. The example of table6-12.xvg involves xeros until 0.04. How come? I want to cut my potential at some point to zero - can I put zeros or shall I specify some value

Re: [gmx-users] User-define non bonded table

2013-06-07 Thread Steven Neumann
On Fri, Jun 7, 2013 at 1:53 PM, Justin Lemkul wrote: > > > On 6/7/13 8:21 AM, Steven Neumann wrote: > >> Thank you. >> Another question... I specify in my table functions e.g. g(x) and h(x) and >> it is written that I need to setup parameters C6 and C12. But where I >> should specify them? In : >

Re: [gmx-users] User-define non bonded table

2013-06-07 Thread Justin Lemkul
On 6/7/13 8:21 AM, Steven Neumann wrote: Thank you. Another question... I specify in my table functions e.g. g(x) and h(x) and it is written that I need to setup parameters C6 and C12. But where I should specify them? In : [ atomtypes ] ;name at.num mass charge ptype V(c6) W(c12) O 8 15.99940

Re: [gmx-users] User-define non bonded table

2013-06-07 Thread Steven Neumann
Thank you. Another question... I specify in my table functions e.g. g(x) and h(x) and it is written that I need to setup parameters C6 and C12. But where I should specify them? In : [ atomtypes ] ;name at.num mass charge ptype V(c6) W(c12) O 8 15.99940 0.000 A 0.22617E-02 0.74158E-06 or [ nonbon

Re: [gmx-users] User-define non bonded table

2013-06-07 Thread Justin Lemkul
On 6/7/13 7:36 AM, Steven Neumann wrote: Thank you, just getting into this. I just dont understand why they start from x=0.04? Why not 0.02 or sth else? You can start the table from whatever value of x that you like, but at a certain point, it is unlikely that particles ever come that close

Re: [gmx-users] User-define non bonded table

2013-06-07 Thread Steven Neumann
Thank you, just getting into this. I just dont understand why they start from x=0.04? Why not 0.02 or sth else? Steven On Fri, Jun 7, 2013 at 11:36 AM, Mohan maruthi sena wrote: > Hi Neumann, > You can use tabulated potential option in > gromacs. Please check the s

Re: [gmx-users] User-define non bonded table

2013-06-07 Thread Mohan maruthi sena
Hi Neumann, You can use tabulated potential option in gromacs. Please check the site given below: http://www.gromacs.org/Documentation/How-tos/Tabulated_Potentials Thanks, Mohan On Fri, Jun 7, 2013 at 3:38 PM, Steven Neumann wrote: > Dear Gmx Users, > > I want to

[gmx-users] User-define non bonded table

2013-06-07 Thread Steven Neumann
Dear Gmx Users, I want to specify a table to mdrun for non bonded parameters. I wish to set it up for all atoms with same potential. Is there any example of the table like this? I want use my specific potential so table should have two columns: X distance [nm] and Y Potential energy {kJ/mol]. Is t