Dear all,

I'm trying to FEP away a TIP4P water molecule from a water box in gmx 4.5.3, but getting a jump in dH/dlambda after some time (around 100 ps), from around -5 to -600 kJ/mol/lambda. I'm using softcore with the following parameters:

sc-alpha = 0.5
sc-power = 1
sc-sigma = 0.3
delta-lambda             = 0
init-lambda = 0.1
couple-lambda0 = vdw
couple-lambda1 = vdw-q
free-energy              = yes

I've also tried using
sc-alpha = 0
sc-power = 0

Any clues what could go wrong?

Could it be due to the virtual sites?

--
David van der Spoel, Ph.D., Professor of Biology
Dept. of Cell & Molec. Biol., Uppsala University.
Box 596, 75124 Uppsala, Sweden. Phone:  +46184714205.
sp...@xray.bmc.uu.se    http://folding.bmc.uu.se
--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to