[gpfsug-discuss] Leave protocol detail info

2016-10-28 Thread Matt Weil
anybody no what this means? Wed Oct 26 20:08:29.619 2016: [D] Leave protocol detail info: LA: 75 LFLG: 24409951 LFLG delta: 75 The materials in this message are private and may contain Protected Healthcare Information or other information of a sensitive nature.

Re: [gpfsug-discuss] GUI and pmsensors/pmcollector

2016-10-28 Thread Markus Rohwedder
t part -- An HTML attachment was scrubbed... URL: < http://gpfsug.org/pipermail/gpfsug-discuss/attachments/20161028/b4552796/attachment-0001.html > -- Message: 2 Date: Fri, 28 Oct 2016 14:22:49 + From: Joshua Akers <ak...@vt.edu> To: gpfsug-

[gpfsug-discuss] GUI and pmsensors/pmcollector

2016-10-28 Thread Michael L Taylor
scom.com/> ___ gpfsug-discuss mailing list gpfsug-discuss at spectrumscale.org http://gpfsug.org/mailman/listinfo/gpfsug-discuss -- next part -- An HTML attachment was scrubbed... URL: < http://gpfsug.org/pipermail/gpfsug-discuss/attachm

Re: [gpfsug-discuss] unified file and object

2016-10-28 Thread Bill Owen
Hi Leslie, For the issues you list below: 1. AD configuration - there is a known issue with quoted names passed to mmuserauth - we are investigating how to correct this. 2. Can you provide more details on how you configured file access? The normal procedure is to use "mmobj file-access

[gpfsug-discuss] GPFS Log Levels

2016-10-28 Thread Joshua Akers
Hi all, I am trying to find more information on GPFS log levels. Here is what I have so far: [D] - Detail info [I] - Info [N] - Notice [W] - Warning [E] - Error [X] - Critical Error [A] - Deadlock related? Any corrections or additional information would be greatly appreciated. Thanks, Josh --

Re: [gpfsug-discuss] GUI and pmsensors/pmcollector

2016-10-28 Thread mark.b...@siriuscom.com
Perhaps I needed more description I have a 3 node cluster 2 NDS’s (with tiebreaker) 1 gui node The NDS’s all have pmsensors installed The gui node had pmcollector installed I’ve modified the /opt/IBM/zimon/ZIMSensors.cfg file on the NSD’s to point to my gui node Systemctl start pmsensors on

Re: [gpfsug-discuss] GUI and pmsensors/pmcollector

2016-10-28 Thread Stefan Schmidt
Hi, the PMCollector must be installed on the same node as the GUI. The collectors can be installed on any node you want to monitor. Hope that helps. Mit freundlichen Grüßen / Kind regards Stefan Schmidt Scrum Master IBM Spectrum Scale GUI / Senior IT Architect/PMP®-Dept. M069 / IBM Spectrum

[gpfsug-discuss] GUI and pmsensors/pmcollector

2016-10-28 Thread mark.b...@siriuscom.com
I am able to do everything I need just fine when I have a single node cluster and both pmsensors and pmcollector are installed all on the same node. When I try and get pmsensors on my NSD nodes and a separate pmcollector elsewhere I never can get anything to show up in the graphs. I’ve

[gpfsug-discuss] SC16 Registration

2016-10-28 Thread Douglas O'flaherty
Greetings: If you haven't yet registered, planned a 1:1 meeting, or interested in a specific topic ... Here you go https://www-01.ibm.com/events/wwe/grp/grp305.nsf/Registration.xsp?openform=357M7UES=en_US=anonymous Sign up so we can plan the cocktail hour on Sunday evening -- Thanks to