Dear all,

I am running a simple test case with a lipid bilayer (DMPC), water, and
ions (150mM KCL) under the influence of a constant electric field ( 300mV,
500mV, and 700mV). *I expected positive and negative ions to separate in
the presence of an external electric field*. However, I am not observing
such behavior despite running the all-atom simulation for 400ns in any
case. I am using gromacs 2018.2, my mdp file is standard charmm-gui
production with electric field option.

for example 500mV electric field in Z-direction :
electric-field-z =      0.060  0     0     0 ; *500**mv  = 8.25nm* 0.060 =
500 mV *


Are there any settings to run the electric field simulation that I miss?
Any help will be greatly appreciated.


Thank you,
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to