Re: [gmx-users] Pressure coupling incorrect number of values (I need exactly 2)-US simulation

2017-08-21 Thread Alex Mathew
Thank you very much, It worked with NVT, but the water molecule is not going though the channel at 0.01 nm per ns but It worked when i increased the pull_coord1_rate to 0.5 nm per ns from 0.01nm per ns but could not get proper histogram and energy profile. What parameters i need to change in

Re: [gmx-users] Pressure coupling incorrect number of values (I need exactly 2)-US simulation

2017-08-20 Thread Alex
The error is actually telling you exactly what is wrong. First relax your system with pressure coupling, then do pull in NVT. Or, possibly adjust the system in such a way that 'direction' pull could be used instead of 'direction-periodic'. Alex On 8/20/2017 1:53 AM, Alex Mathew wrote:

Re: [gmx-users] Pressure coupling incorrect number of values (I need exactly 2)-US simulation

2017-08-20 Thread Alex Mathew
Dear Justin, As per the manual i have changed parameters as tcoupl = berendsen tc_grps = Protein Non-Protein Chain_B tau_t = 1.01.01.0 ref_t = 310 310 310 ; pcoupl = berendsen pcoupltype

Re: [gmx-users] Pressure coupling incorrect number of values (I need exactly 2)-US simulation

2017-08-19 Thread Justin Lemkul
On 8/19/17 8:23 AM, Alex Mathew wrote: Dear all, In order to obtain the PMF diagram of a water molecule through membrane protein channel, I set up a simulation system and try to run with pull_coord1_geometry= direction-periodic. To correct te error following changes are made in the mdp

[gmx-users] Pressure coupling incorrect number of values (I need exactly 2)-US simulation

2017-08-19 Thread Alex Mathew
Dear all, In order to obtain the PMF diagram of a water molecule through membrane protein channel, I set up a simulation system and try to run with pull_coord1_geometry= direction-periodic. To correct te error following changes are made in the mdp file {error (Can not have dynamic box while