Re: [PATCH] EFI: console: Fix the "enter" key not working on X86 tablets

2018-07-04 Thread Daniel Kiper
On Tue, Jun 26, 2018 at 08:15:01PM +0200, Hans de Goede wrote: > Most 8" or 7" x86 Windows 10 tablets come with volume up/down buttons and > a power-button. In their UEFI these are almost always mapped to arrow > up/down and enter. > > Pressing the volume buttons (sometimes by accident) will stop t

[PATCH] EFI: console: Fix the "enter" key not working on X86 tablets

2018-06-26 Thread Hans de Goede
Most 8" or 7" x86 Windows 10 tablets come with volume up/down buttons and a power-button. In their UEFI these are almost always mapped to arrow up/down and enter. Pressing the volume buttons (sometimes by accident) will stop the menu countdown, but the power-button / "enter" key was not being reco