Thanks Peter
I read the manual and I will change the parameter for test.
Best Regards
Jorge Arueira Campos
CEF-OSASCO-SP BRAZIL
On 7/27/06, Hunkeler Peter (KIUB 34) <[EMAIL PROTECTED]>
wrote:
Reading the manual "Seting up a sysplex" it appears to me
that wildcards are not permitted in the R
Reading the manual "Seting up a sysplex" it appears to me
that wildcards are not permitted in the RESTART_METHOD parm.
Try "RESTART_METHOD(BOTH,STC,'S &SYSELEM.')" instead.
Link to the FM: http://tinyurl.com/m7uce
Peter Hunkeler
CREDIT SUISSE
---
-- Forwarded message --
From: Jorge Arueira Campos <[EMAIL PROTECTED]>
Date: Jul 25, 2006 10:40 PM
Subject: ARM RESTART MANAGER
To: IBM-MAIN@bama.ua.edu
Hi Again
I need information about ARM Restart. In my shop I codified a policy of
restart for my STC's with the onl
Hi Again
I need information about ARM Restart. In my shop I codified a policy of
restart for my STC's with the only start for products of file
transfers. When I IPL the driving system, the restart do not occours in the
target system(SSP2), the sample and the syslog below. Anybody have a sample
of