Jim Mulder wrote:
Well, of course it does. The purpose of the DUMP and REIPL
options of V XCF,sys,OFF,etc. is simply to set the 0A2 wait
state reason code to a value which drives the appropriate AutoIPL
actions as defined in the WSAT (Wait State Action Table).
See MVS Planning: Operations
> For those present in Seattle for the very successful Session 2007: Ask
> the Experts & MVS Program Closing, there was some disagreement about
> whether V XCF,sys,OFF,REIPL would honor the AUTOIPL MVS settings in
> DIAGxx or always re-IPL with the last settings used.
>
> Empirical evidence bei
For those present in Seattle for the very successful Session 2007: Ask
the Experts & MVS Program Closing, there was some disagreement about
whether V XCF,sys,OFF,REIPL would honor the AUTOIPL MVS settings in
DIAGxx or always re-IPL with the last settings used.
Empirical evidence being the best
3 matches