Re: Does VVDS must be catalogued ?

2007-03-02 Thread Tom Marchant
On Thu, 1 Mar 2007 14:01:30 +0100, CAPRON Romain <[EMAIL PROTECTED]> wrote: > >DEFINE CLUSTER (NAME(SYS1.VVDS.Vvolser) - >NIXD VOL(volser) - >TRK(45,1)) > That seems to me to be kind of a strange way to allocate them. The default allocation is TRK(5,5) That allows

Re: RE : Does VVDS must be catalogued ?

2007-03-01 Thread Richards.Bob
To: IBM-MAIN@BAMA.UA.EDU Subject: RE : Does VVDS must be catalogued ? But when you defined it with the following statement: DEFINE CLUSTER (NAME(SYS1.VVDS.Vvolser) - NIXD VOL(volser) - TRK(45,1)) It is automatically catalogued

RE : Does VVDS must be catalogued ?

2007-03-01 Thread CAPRON Romain
Système MATMUT, France -Message d'origine- De : IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] De la part de Richards.Bob Envoyé : jeudi 1 mars 2007 14:05 À : IBM-MAIN@BAMA.UA.EDU Objet : Re: Does VVDS must be catalogued ? Short answer - NO And it does not have to be cata

Re: Does VVDS must be catalogued ?

2007-03-01 Thread Richards.Bob
Short answer - NO And it does not have to be cataloged. Bob Richards -Original Message- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of CAPRON Romain Sent: Thursday, March 01, 2007 8:02 AM To: IBM-MAIN@BAMA.UA.EDU Subject: Does VVDS must be catalogued

Does VVDS must be catalogued ?

2007-03-01 Thread CAPRON Romain
Hello, I'm wondering if the VVDS "MUST" be cataloged or not... All of our VVDS have the following file naming convention : SYS1.VVDS.Vvolser And are definied as with this IDCAMS statement : DEFINE CLUSTER (NAME(SYS1.VVDS.Vvolser) - NIXD VOL(volser) -