Re: Problem changing pools for HSM tape output

2008-04-19 Thread Chris Taylor
Dave, Glad it's working. The only other thing I could think of was that HSM was finding mixed device types (e.g. both 3490 and 3590) under the same esoteric. It does not like that, squawks during startup, and will ignore the SETSYS command setting the units. Just for future reference.

Re: Problem changing pools for HSM tape output

2008-04-19 Thread O'Brien, David W. (NIH/CIT) [C]
s, Dave O'Brien From: Chris Taylor [] Sent: Sat 4/19/2008 12:12 PM To: IBM-MAIN@BAMA.UA.EDU Subject: Re: Problem changing pools for HSM tape output Dave, I am not very familar with HSC workings, but shouldn't your HSM unit parms be pointing to L9840? Alternatively, are the 9840's

Re: Problem changing pools for HSM tape output

2008-04-19 Thread Chris Taylor
Dave, I am not very familar with HSC workings, but shouldn't your HSM unit parms be pointing to L9840? Alternatively, are the 9840's genned as 3590's? Maybe using 3590 in the HSM parms instead of 3490 might work? Regards, Chris Taylor --

Problem changing pools for HSM tape output

2008-04-18 Thread O'Brien, David W. (NIH/CIT) [C]
I need another pair of eyes, can somebody see what I'm doing wrong? We are attempting to change the pool to which HSM writes its output. We were outputting HSM Backup and ML2 tapes to tape range E01-E01000 and duplexing to Q01-Q01000 We want to go back to H0 for Primary Backup, H1nnn