Re: Question on cics and osa-icc consoles

2009-02-12 Thread larry macioce
Thanks for the quick reply. In reading defining mcs consoles to cics it says to give it the 8 character name of the console from the consolxx parmlib member. But in the mvs init and tuning guide it said the name could be 2-8 characters so I only made it 7. Is cics going to regurgitate the 7 charact

Re: Question on cics and osa-icc consoles

2009-02-12 Thread Brian Peterson
I would suggest that you check the console names you've given your new consoles, and compare them to the names you used previously. The console name I'm talking about is the NAME parameter of the CONSOLE statement in SYS1.PARMLIB(CONSOLnn). Maybe you gave your new ICC consoles new names, and didn

Re: Question on cics and osa-icc consoles

2009-02-12 Thread larry macioce
Yes, the operators must sign on to the consoles.thx Mace On Thu, Feb 12, 2009 at 9:39 AM, Andy White wrote: > Do you have RACF turned on to your consoles, basically do you operators > need to sign on to use a console? I got burnt on that, I need to have them > defined to CICS the new names of th

Re: Question on cics and osa-icc consoles

2009-02-12 Thread Andy White
Do you have RACF turned on to your consoles, basically do you operators need to sign on to use a console? I got burnt on that, I need to have them defined to CICS the new names of the consoles and to RACF. Andy S. White "IBM Mainframe Discussion List" wrote on 02/12/2009 09:25:34 AM: >

Question on cics and osa-icc consoles

2009-02-12 Thread Larry Macioce
We have just moved our consoles from 3x74 to osa-icc connection. We ipled for the first time last night an I got a call that cics didn't recognize the consoles. Can any one help me in the definiton of this type of console? In the iocds they are defined as 3270-x, is this the only change I'll ne