Hi,
Is it possible to tell DFSMShsm to not backup empty files?
Gadi
? ?? ? ?? ??? ??? ?? ? ??? ??
??. ?? , ?? ??? ?, ??? ? ?? ???
? ?? ?? ?. ? ? ?? ?? ?? ?? ??
Thanks Tom! That is exactly what I was looking for.
I also want to thank a couple of people who sent me off-list messages,
but they'd prefer to remain anonymous.
Dave
At 12/29/2018 10:23 PM, Tom Conley wrote:
On 12/28/2018 5:41 PM, David Cole wrote:
Hi,
I'm looking for an IBM written mappin
On 12/27/18 11:36 AM, Paul Gilmartin wrote:
> On Wed, 26 Dec 2018 08:28:07 -0500, Mark Regan wrote:
>
>> https://www.computerworld.com/article/3330396/application-development/situation-normal-all-fudged-up.html
>>
> Did I miss something? Did it describe the "one adjustment," on the "One card"
> th
Peter ,
Do customers typically add their own SYS type symbols ? I am curious.
Scott
On Sun, Dec 30, 2018 at 8:44 AM Peter Relson wrote:
> Using IEASYMU2 is fine.
>
> I suspect that most would not use "routinely" to express the desirability
> of IBM providing a symbol for "yesterday".
> I have
PGF is software that uses GDDM; the 3270 graphics protocols are APA and PSS.
APA came in with the IBM 3270 Personal Computer (3270-PC) and PSS came in with
the 3278 and 3279.
--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3
From: IBM Mainframe D
R'Shmuel,
It probably means PGF.
Regards,
David
On 2018-12-30 15:49, Seymour J Metz wrote:
> What are "GDDM graphics"? GDDM supports two very different 3270 for graphics.
>
>
> --
> Shmuel (Seymour J.) Metz
> https://eur03.safelinks.protection.outlook.com/?url=http:%2F%2Fmason.gmu.edu%2F~smetz3&d
What are "GDDM graphics"? GDDM supports two very different 3270 for graphics.
--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3
From: IBM Mainframe Discussion List on behalf of
Dave Jones
Sent: Sunday, December 30, 2018 1:02 PM
To: IBM-MAIN@LIST
I'm a big fan of Vista TN3270just wish it ran on Linux (and supported GDDM
graphics).
DJ
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAI
From scratch? The second COBOL program I ever wrote started with the first one
as a model/skeleton. We seldom create from scratch if we can help it. I'd say
what you're suggesting is very doable with one proviso: you need physical
connection from the z12 to peripherals--at least DASD--and to the
Using IEASYMU2 is fine.
I suspect that most would not use "routinely" to express the desirability
of IBM providing a symbol for "yesterday".
I have not seen a requirement for such a thing (this would be a "dynamic
symbol" rather than a "static symbol").
FWIW, at this point, compatibility would b
Hi
We recently moved from zec12 to z14 and routers all connections ,storage,
tapes to the new hardware.
So as of now zec12 doesn't have any workload. So it will be just active for
few months. Is it possible to build an LPAR from scratch using the new
machine and move it to zec12 just for a practi
Hello David,
Thanks for reply. I have set below parameter in my SYSLOG parm file. But
# The following are example statements that illustrate how to
# configure automatic archival. See the section on syslogd rules for
# details about specifying rules.
#
ArchiveTimeOfDay 11:10
12 matches
Mail list logo