Re: IODF address

2020-12-16 Thread kekronbekron
Just me being dumb.. what do you mean by 'IODF volume moved'? - KB ‐‐‐ Original Message ‐‐‐ On Thursday, December 17, 2020 10:06 AM, Steve Horein wrote: > Thanks! > It looks like I get the same behavior with what Mark uses: > > IPALPDDV = Storage(D2x(ECVTIPA + 92),4) /* load parm dev

Re: IODF address

2020-12-16 Thread Steve Horein
Thanks! It looks like I get the same behavior with what Mark uses: IPALPDDV = Storage(D2x(ECVTIPA + 92),4)/* load parm dev number */ On a system that had the IODF volume "moved", the old address is also present in IPALPDDV. Bummer. On Wed, Dec 16, 2020 at 8:15 PM kekronbekron <

Re: IODF address

2020-12-16 Thread kekronbekron
Hi Steve, This should be in Mark Zelden's IPLINFO source code - http://www.mzelden.com/mvsfiles/iplinfo.txt - KB ‐‐‐ Original Message ‐‐‐ On Wednesday, December 16, 2020 10:29 PM, Steve Horein wrote: > Hi! > I am able to determine the IODF unit address from IPAIODFU in IPA. However,

ZEKE15B Asistance

2020-12-16 Thread David Spiegel
Hi, Does anyone have experience with coding ZEKE15B (security exit for ASG  ZEKE)? In particular, I'd like to set a SLIP to look at the registers and storage at the time of invocation. Also, other than having the load module in the //STEPLIB or LNKLST, are there parameter(s) that need to be

Re: GIM69207S error on SMP/E RECEIVE ORDERSERVER

2020-12-16 Thread Richards, Robert B. (CTR)
Okay, stand down, my friends. A coworker helped me to discover the real culprit: Websense! Sent a note to Network Security (thanks Gadi, you were right on) to add the HTTPS urls back to the whitelist. (A least it isn't Solarwinds ) Bob -Original Message- From: IBM Mainframe

Re: GIM69207S error on SMP/E RECEIVE ORDERSERVER

2020-12-16 Thread Carmen Vitullo
HTTPS? do you need to authenticate thru a proxy server ? Carmen Vitullo -Original Message- From: Robert <01c91f408b9e-dmarc-requ...@listserv.ua.edu> To: IBM-MAIN Date: Wednesday, 16 December 2020 1:56 PM CST Subject: Re: GIM69207S error on SMP/E RECEIVE ORDERSERVER The ID

Re: GIM69207S error on SMP/E RECEIVE ORDERSERVER

2020-12-16 Thread Richards, Robert B. (CTR)
The ID has not changed nor have the certs associated with the keyring. And none of the certs have expired. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Carmen Vitullo Sent: Wednesday, December 16, 2020 2:53 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: GIM69207S

Re: GIM69207S error on SMP/E RECEIVE ORDERSERVER

2020-12-16 Thread Carmen Vitullo
Bob, I've had this issue myself, it was, for me self inflicted, I have 2 mainframe ID's, only one has the cert connected, if I use the correct ID, or specify my correct id with the cert name It works, maybe this is it? On Wed, 16 Dec 2020 19:38:49 +, Gadi Ben-Avi wrote: >Hi, >When I

Re: GIM69207S error on SMP/E RECEIVE ORDERSERVER

2020-12-16 Thread Gadi Ben-Avi
Hi, When I got this type of error, it turned out to be a problem with one of our network security products. I'm not sure if it was the FireWall or something else. I would ask the network security team. Gadi From: IBM Mainframe Discussion List on behalf

GIM69207S error on SMP/E RECEIVE ORDERSERVER

2020-12-16 Thread Richards, Robert B. (CTR)
Just got this today: GIM69207S ** RECEIVE PROCESSING HAS FAILED BECAUSE THE CONNECTION WITH THE SERVER FAILED. javax.net.ssl.SSLHandshakeException: com.ibm.jsse2.util.h: PKIX path building failed: com.ibm.security.cert.IBMCertPathBuilderException: unable to

IODF address

2020-12-16 Thread Steve Horein
Hi! I am able to determine the IODF unit address from IPAIODFU in IPA. However, this value becomes stale if the address changes when the storage folks move disk around. I can see the MVS command DISPLAY IPLINFO accounts for those changes in message IEE254I: IEE254Ihh.mm.ss IPLINFO DISPLAY

Using HSM Transition to clear MOD-3 devices

2020-12-16 Thread Chuck Kreiter
I've been working with the HSM function to move datasets off of MOD-3 devices. I'm testing out the feature to code Serialization Error Exit = DB2 in the management class to invoke the DB2 CAF interface to close and unallocate DB2 tables if they aren't in use. I'm getting an 806 abend when DSS

Re: IXGLOGR - system logger

2020-12-16 Thread Robert Garrett
How is the log stream defined? Are the offload datasets (and staging datasets, if specified) SMS managed? (LS_STORCLASS() and STG_STORCLASS() specified with values and not with NO_LS_STORCLASS and NO_STG_STORCLASS respectively) If so, then check the associated storage group to see if it's out