Re: Continuing a reply during IPL

2024-05-06 Thread Binyamin Dissen
On Sat, 4 May 2024 08:57:52 -0500 Giliad Wilf <00d50942efa9-dmarc-requ...@listserv.ua.edu> wrote: :>On Sat, 4 May 2024 03:55:45 -0500, Giliad Wilf wrote: :>>On Mon, 22 Apr 2024 15:17:47 +0300, Binyamin Dissen wrote: :>>>Saw the example, tried with and without quotes. No luck. . :>>Sorry,

Re: Continuing a reply during IPL

2024-05-04 Thread Giliad Wilf
On Sat, 4 May 2024 03:55:45 -0500, Giliad Wilf wrote: >On Mon, 22 Apr 2024 15:17:47 +0300, Binyamin Dissen > wrote: > >>Saw the example, tried with and without quotes. No luck. >> >. >. >. >Sorry, I only saw this post yesterday. >I've forced IPL to issue msg. IEA101A by changing IMSI char. from

Re: Continuing a reply during IPL

2024-05-04 Thread Giliad Wilf
On Mon, 22 Apr 2024 15:17:47 +0300, Binyamin Dissen wrote: >Saw the example, tried with and without quotes. No luck. > . . . Sorry, I only saw this post yesterday. I've forced IPL to issue msg. IEA101A by changing IMSI char. from M to T in IPL parameter. First, I've specified SYSP=DW, because o

Re: Continuing a reply during IPL

2024-04-22 Thread Binyamin Dissen
Saw the example, tried with and without quotes. No luck. On Mon, 22 Apr 2024 05:58:20 -0500 Steve Horein <05b0b4f1358b-dmarc-requ...@listserv.ua.edu> wrote: :>I found this example in the doc ( :>https://www.ibm.com/docs/en/zos/2.4.0?topic=command-specifying-system-parameters1 :>): :>R 00,'MLP

Re: Continuing a reply during IPL

2024-04-22 Thread Steve Horein
I found this example in the doc ( https://www.ibm.com/docs/en/zos/2.4.0?topic=command-specifying-system-parameters1 ): R 00,'MLPA=(00,01,02,CONT' IEA116A CONTINUE SYSTEM PARAMETERS R 00,'03,L),BLDL=02' Perhaps single quotes are required, or fully padded '00' replyID? A search in the commands doc d

Continuing a reply during IPL

2024-04-22 Thread Binyamin Dissen
I had an occasion where the IEASYS PROG= entry was messed up (period in place of a comma). Cannot access the data. Using a similar system I worked out a PROG= list to use, however the list was too long for the reply command. I was able to specify R 00,PROG=(list,CONT and was prompted to contin