Re: IEC190I message

2015-01-08 Thread Elardus Engelbrecht
Ken MacKenzie wrote: >Sorry, forgot to change the subject. Its allright, year 2015 is still running AFAIK. ;-D >I have a DCB set up with a DCBE parameter. I'm running in 31-bit mode and I >copy the DCB below the line. On my OPEN I get the following message: Just like Lizette, I'm asking too

Re: IEC190I message

2015-01-08 Thread Greg Dyck
Make sure the storage for the DCBE has the same storage key as the DCB, contains the constant 'DCBE' in the first 4 bytes, and has a minimum length value of 56 in the halfword that follows the constant 'DCBE'. Greg -- For IBM-M

Re: IEC190I message

2015-01-08 Thread Lizette Koehler
:15 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: IEC190I message Sorry, forgot to change the subject. From: Ken MacKenzie To: IBM-MAIN@LISTSERV.UA.EDU, Date: 08/01/2015 16:13 Subject:Re: Changing Service Class Sent by:IBM Mainframe Discussion List Hi I wonder if anyone

IEC190I message

2015-01-08 Thread Ken MacKenzie
Sorry, forgot to change the subject. From: Ken MacKenzie To: IBM-MAIN@LISTSERV.UA.EDU, Date: 08/01/2015 16:13 Subject:Re: Changing Service Class Sent by:IBM Mainframe Discussion List Hi I wonder if anyone can help point me in the right direction. I have a DCB set u