AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: (External):Re: Message IEF302A
*** EXTERNAL EMAIL - Use caution when opening links or attachments ***
Explanation
The external writer is waiting for the operator to validate writer name
. The writer name was specified on a SYSOUT DD statement
/gg302a.htm
So, it would seem the correct response is R xx,D to use the default writer.
Joe
On Thu, Dec 31, 2020 at 12:50 PM Jesse 1 Robinson
wrote:
> We've had a couple of instances recently of message IEF302A:
>
> jobname WTR WAITING TO START FOR JOBID
>
> We sort
We've had a couple of instances recently of message IEF302A:
jobname WTR WAITING TO START FOR JOBID
We sort of interpreted it as an ENQ conflict, except that there are no actual
data sets involved. It seems to revolve around a job calling for a particular
WTR, very unusual