Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question How about ATTACH JSTCB=YES

2016-09-25 Thread J R
I don't think so. Even with JSTCB=YES, it's stil in the same step, so the initiator doesn't get involved. Sent from my iPhone > On Sep 25, 2016, at 16:32, Joseph Reichman wrote: > > Hi > > JR I think it's after the jobstep > > That the disp takes effect > > I know you have to be authoriz

Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question How about ATTACH JSTCB=YES

2016-09-25 Thread Joseph Reichman
Hi JR I think it's after the jobstep That the disp takes effect I know you have to be authorized for this But if I attach the assembler with JSTCB=YES The disp will happen Yes? > On Sep 25, 2016, at 3:31 PM, Paul Gilmartin > <000433f07816-dmarc-requ...@listserv.ua.edu> wrote: > >> On

Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question

2016-09-25 Thread Paul Gilmartin
On 2016-09-25, at 12:38, Charles Mills wrote: > > Z/os ftp server can retrieve sysout but not sure that ftp clent can. > That may depend on whether the client can issue the QUOTE command. Most command line clients can; many GUI clients hid it under some name such "Send Command". Is the OP runn

Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question

2016-09-25 Thread Joseph Reichman
The sysin dataset to the assembler is opened And closed Before I BASSM to the assembler while under test I can go to a different TSO I'd and browse the dataset I'm thinking of allocating the sysprint opening and closing it and then BASSM to the assembler and in that case I maybe able to see

Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question

2016-09-25 Thread Joe Reichman
ubject: Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question No. It's the FREE or end-of-step that triggers the DISP. Did you try the DALCLOSE that you mentioned? Sent from my iPhone > On Sep 25, 2016, at 14:18, Joseph Reichman wrote: > > This is all very surprising

Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question

2016-09-25 Thread Charles Mills
@LISTSERV.UA.EDU Subject: Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question Charles I don't know if this solution will work for me I would like to FTP the assembler listing to my PC Don't think can do this with a SYSOUT class  -Original Message- From: IBM Mainfra

Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question

2016-09-25 Thread J R
No. It's the FREE or end-of-step that triggers the DISP. Did you try the DALCLOSE that you mentioned? Sent from my iPhone > On Sep 25, 2016, at 14:18, Joseph Reichman wrote: > > This is all very surprising to me > > Doesn't the assembler CLOSE sysprint > > If so wouldn't the CLOSE catalo

Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question

2016-09-25 Thread Joseph Reichman
This is all very surprising to me Doesn't the assembler CLOSE sysprint If so wouldn't the CLOSE catalogue the dataset > On Sep 25, 2016, at 2:15 PM, Paul Gilmartin > <000433f07816-dmarc-requ...@listserv.ua.edu> wrote: > >> On Sun, 25 Sep 2016 13:47:15 -0400, Joe Reichman wrote: >> >> C

Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question

2016-09-25 Thread Paul Gilmartin
On Sun, 25 Sep 2016 13:47:15 -0400, Joe Reichman wrote: >Charles I don't know if this solution will work for me I would like to FTP >the assembler listing to my PC > >Don't think can do this with a SYSOUT class > Perhaps you can with the FTP command QUOTE FILETYPE=JES >I was able to allocate the

Re: S99ERROR = 21C For &&OBJ UNIT=VIO SYSOUT Class Question

2016-09-25 Thread Joe Reichman
Charles I don't know if this solution will work for me I would like to FTP the assembler listing to my PC Don't think can do this with a SYSOUT class -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Charles Mills Sent: Sunday, Septem