Re: Storage Zoning clarification

2021-05-12 Thread Peter Vander Woude
Yes it does. From the HCD manual, there's a section that talks about them Defining a special FBA device (FBA) You can use a new type of disk devices, known as Fixed Block Architecture (FBA) or Fixed Block (FB) devices. Devices of this type may be considered as a data bridge between z/OS

Re: Storage Zoning clarification

2021-05-11 Thread Seymour J Metz
[pwo...@harristeeter.com] Sent: Tuesday, May 11, 2021 12:46 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Storage Zoning clarification FCP connected SCSI drives is done via san zoning. Considering that IOSFBA is a function within z/OS. I don't know how that connectivity works. Peter On Tue, 11

Re: Storage Zoning clarification

2021-05-11 Thread Peter Vander Woude
FCP connected SCSI drives is done via san zoning. Considering that IOSFBA is a function within z/OS. I don't know how that connectivity works. Peter On Tue, 11 May 2021 15:47:31 +, Seymour J Metz wrote: >What about IOSFBA and FCP connected SCSI drives? > > >-- >Shmuel (Seymour J.) Metz

Re: Storage Zoning clarification

2021-05-11 Thread Seymour J Metz
, 2021 9:39 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Storage Zoning clarification I can comment on this, as I do san admin (along with z/OS and a couple of other things). >From the z/OS perspective, it only deals with 3390 dasd architecture, and >3490/3590 tapes, and is connected via FICON,

Re: Storage Zoning clarification

2021-05-11 Thread Peter Vander Woude
I can comment on this, as I do san admin (along with z/OS and a couple of other things). From the z/OS perspective, it only deals with 3390 dasd architecture, and 3490/3590 tapes, and is connected via FICON, which may or may not go thru a FICON director. On the ficon director there is a

Re: Storage Zoning clarification

2021-05-10 Thread Radoslaw Skorupka
I think, there is some misunderstanding here. First, basics: DAS - Direct Attached Storage - a disk connected directly, like your HDD in your PC. This model can be used in mainframe world - DASD array connected over FICON links to the host. No switches/directors between. SAN - In this case

Re: Storage Zoning clarification

2021-05-10 Thread Jake Anderson
Hi So from the mainframe perspective zoning is done even if the connectivity passes through SAN ? Sorry if my understanding is incorrect ? Jake On Mon, 10 May, 2021, 2:32 pm Radoslaw Skorupka, wrote: > W dniu 10.05.2021 o 06:36, Jake Anderson pisze: > > Hello All, > > > > Good evening > > > >

Re: Storage Zoning clarification

2021-05-10 Thread Radoslaw Skorupka
W dniu 10.05.2021 o 06:36, Jake Anderson pisze: Hello All, Good evening I am trying to understand on how the ZONING part works when the connectivity to storage box or the tape device goes through a SAN switch. How does the ZONING is done and is there any documentation with an example to

Storage Zoning clarification

2021-05-09 Thread Jake Anderson
Hello All, Good evening I am trying to understand on how the ZONING part works when the connectivity to storage box or the tape device goes through a SAN switch. How does the ZONING is done and is there any documentation with an example to understand better. I am trying to google to see if I can