Re: TN3270E TNPROFx question

2020-09-28 Thread Jantje.
On Sun, 27 Sep 2020 19:23:03 -0400, Tony Thigpen wrote: >I want TN3270E connections on a specific port to display the VTAM USSTAB >instead of going directly into CICS. But, if I take the existing >"DEFAULTAPPL PRODCICS" out of the TNPROF0 member, I am getting what I >think is the 'solicitor' pane

Re: TN3270E TNPROFx question (resolved)

2020-09-27 Thread Tony Thigpen
Simple resolution. Just needed to had my VTAMLIB to the STEPLIB for the TN3270E job. I am surprised that it was not already in the job. Tony Thigpen Tony Thigpen wrote on 9/27/20 7:23 PM: I want TN3270E connections on a specific port to display the VTAM USSTAB instead of going directly into C

TN3270E TNPROFx question

2020-09-27 Thread Tony Thigpen
I want TN3270E connections on a specific port to display the VTAM USSTAB instead of going directly into CICS. But, if I take the existing "DEFAULTAPPL PRODCICS" out of the TNPROF0 member, I am getting what I think is the 'solicitor' panel and not the USSTAB I set up. I have a valid USSTAB that