On Sun, 27 Sep 2020 19:23:03 -0400, Tony Thigpen wrote:
>I want TN3270E connections on a specific port to display the VTAM USSTAB
>instead of going directly into CICS. But, if I take the existing
>"DEFAULTAPPL PRODCICS" out of the TNPROF0 member, I am getting what I
>think is the 'solicitor' pane
Simple resolution.
Just needed to had my VTAMLIB to the STEPLIB for the TN3270E job.
I am surprised that it was not already in the job.
Tony Thigpen
Tony Thigpen wrote on 9/27/20 7:23 PM:
I want TN3270E connections on a specific port to display the VTAM USSTAB
instead of going directly into C
I want TN3270E connections on a specific port to display the VTAM USSTAB
instead of going directly into CICS. But, if I take the existing
"DEFAULTAPPL PRODCICS" out of the TNPROF0 member, I am getting what I
think is the 'solicitor' panel and not the USSTAB I set up.
I have a valid USSTAB that