AW: Re: Will zIIP-eligible work unit loose zIIP-eligibility when executed on CP?

2018-08-07 Thread Peter Hunkeler
>It is kept. I have PAUSED and RELEASED a WU lots of times. Mostly, it runs >on the zIIP, but sometimes it runs on a CP due to the zIIP being busy. Thanks a lot. Much appreciated. This is in line with my expectation. -- Peter Hunkeler ---

Re: Will zIIP-eligible work unit loose zIIP-eligibility when executed on CP?

2018-08-07 Thread Christopher Y. Blaicher
] On Behalf Of Peter Hunkeler Sent: Tuesday, August 7, 2018 4:33 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Will zIIP-eligible work unit loose zIIP-eligibility when executed on CP? Cross-posted to IBM-MAIN and MXG-L Out of curiosity: Regarding the zIIP eligibility, what happens to a zIIP-eligible

Will zIIP-eligible work unit loose zIIP-eligibility when executed on CP?

2018-08-07 Thread Peter Hunkeler
Cross-posted to IBM-MAIN and MXG-L Out of curiosity: Regarding the zIIP eligibility, what happens to a zIIP-eligible work unit when it is dispatched on a CP because the zIIPs are too busy (zIIP-on CP)? Will the work unit loose its zIIP-eligible state (flag)? Assume the WU is dispatched on the