Not only that, you must have a z10 to create your initial 6.1 system. It cannot
even be ordered until you have one and the system you DDR is a 6.1 system.
Regards,
Richard Schuh
From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf
Regards,
Richard Schuh
From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf
Of O'Brien, Dennis L
Sent: Friday, January 22, 2010 4:37 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: z/VM 6.1 Delivery
Richard,
The books are all in one
Apparently the books are customized. I found no mention of the single zip, but
I have prevailed.
IBM may have considered it and decided that a different delivery system was
required for security or the bottom line. The other possibility is that they
wanted a single delivery system for DVD and
Hi everyone,
Someone asked on IBM-MAIN about the tech conferences--sorry I should
have posted this sooner. My boo-boo.
Here are the dates for two upcoming IBM System z Technical Conferences
(renamed to Technical University).
Here's the link to the events calendar where you can find these
On Mon, Jan 25, 2010 at 1:47 PM, Pamela Christina (a rainy day in
Endicott) chris...@gdlvm7.vnet.ibm.com wrote:
IBM System z Technical University (formerly Technical Conference)
May 17-21, 2010
Berlin, Germany - Hotel Berlin
(Open for enrollments)
What is the cost of the IBM Conference in Boston?
-Original Message-
From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Pamela Christina (a rainy day in Endicott)
Sent: Monday, January 25, 2010 10:47 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: 2010 IBM System z
Velocity Software has scheduled Performance Days during April in NY,
Washington DC, Mountain View, and Dallas. We are also providing a 4 day
Performance Workshop the week following SHARE (March 22) and waiving the fee
on
this program. (A savings of $995.) Seating is limited to 16
Hello all,
Trying to IPL VM/ESA 2.4 on an old MP2000. The box IPLs OK, but when tring to
vary the
OSA online I get the HCPCPN6283I... message. I do a QUERY on the device and VM
shows
it as an OSA, but it's offline. Any ideas?
Thanks,
Billy
Billy,
From a CMS userid on that system, did you try entering: HELP HCPCPN6283I
Doing that on our system shows:
---snip---
(c) Copyright IBM Corporation 1990, 2004
HCP6283I Device rdev cannot be varied online because no channel path is
available.
Explanation: The
On 01/25/2010 05:19 PM, Billy Bingham wrote:
Hello all,
Trying to IPL VM/ESA 2.4 on an old MP2000. The box IPLs OK, but when
tring to vary the OSA online I get the HCPCPN6283I... message. I do a
QUERY on the device and VM shows it as an OSA, but it's offline. Any
ideas?
Thanks,
Billy
I'm not able to load an OAT because I can't vary it online. Is there a hardware
command to
re-set the device to the original OAT? Should I just have only devices 0 1
defined in the
IOCDS?
This is what I have defined now:
CNTLUNIT CUNUMBR=1100,PATH=(34),UNIT=OSA
| Fixed typo.
| Answers to some of the questions that were asked.
|
| Renaming: as I understand it, many of the conferences are renamed
| to Technical University.
|
| Registration: z Boston TU is not open for enrollment yet so I don't
| know the registration fee. Sorry.
|
In the pages linked, especially the one regarding getting management approval,
the dreaded word conference is still used. That may make it a no-go in some
quarters.
Regards,
Richard Schuh
-Original Message-
From: The IBM z/VM Operating System
[mailto:ib...@listserv.uark.edu]
thanks for your help
the solution I work correctly
Thanks to all
Atte
Victor Hugo
2010/1/21 P S zosw...@gmail.com
On Thu, Jan 21, 2010 at 9:08 PM, P S zosw...@gmail.com wrote:
'CP SPOOL PUNCH CONT'
'PUNCH SCRIPT LINUX A'
parse value diag(8, 'SPOOL PUNCH CLOSE NOCONT') with . .
Hello
Continuous with this subject, trying to find the solution most direct and
simple to realise it.
I want that dump and restore everything from VM and not to involve in this
to the tools linux .
And I have another question:
With DFSMS for z/vm it's possible this???
Dump and restore between
Varying the CHPID off, then on is supposed to reset it. But check your
FE device (111F), it is the device that is used to load the OAT.
On 01/25/2010 05:54 PM, Billy Bingham wrote:
I'm not able to load an OAT because I can't vary it online. Is there a
hardware command to re-set the device to
It depends what you need to restore. DFSMS/VM's COPY command can copy CMS
formatted minidisks to unlike disks, so also from 3390 to FBA. The VM spool
for example need to be rebuilt and transferred using tape; MAINT 190, with
its CMS nucleus, needs to be rebuilt too, sameway for SAPL.
2010/1/26