Hi Frank,

  We are still running on our tServer with FLEX-ES 6.x. and z/VM 4.4 and
z/VSE 3.1.2.  We run the hardware on GMT
  and use the z/VM system config file to recognize IPL's for daylight
savings.  We do ours on Friday afternoon at 3:30 since
  we don't have a shift running on either Sat or Sun.  

  This time we had a strange error where the FLEX console could not find
the VM IPL terminal.  I think it is because we also
  changed the UNIX time to adjust to the constant "drift" that we see
with the system time (FLEX/UNIX always ends up
  running a minute or so fast over a few months).  To compensate, we
changed our procedure to always do an INIT 6 on 
  the tServer after we change the clock for drift compensation.

  Here is our system config:

/**********************************************************************/

/*                        TIMEZONE DEFINITIONS                        */

/**********************************************************************/

                                                                        

    TimeZone_Definition CDT West 05.00.00                               

    TimeZone_Definition CST West 06.00.00                               

                                                                        

    TimeZone_Boundary on 2006-03-31 at 11:00:00 to CDT                  

    TimeZone_Boundary on 2006-10-27 at 11:00:00 to CST                  

    TimeZone_Boundary on 2007-03-09 at 11:00:00 to CDT                  

    TimeZone_Boundary on 2007-11-02 at 11:00:00 to CST                  

    TimeZone_Boundary on 2008-03-07 at 11:00:00 to CDT                  

    TimeZone_Boundary on 2008-10-31 at 11:00:00 to CST                  

    TimeZone_Boundary on 2009-03-06 at 11:00:00 to CDT                  

    TimeZone_Boundary on 2009-10-30 at 11:00:00 to CST                  

    TimeZone_Boundary on 2010-03-12 at 11:00:00 to CDT                  

    TimeZone_Boundary on 2010-11-05 at 11:00:00 to CST                  

    TimeZone_Boundary on 2011-03-11 at 11:00:00 to CDT                  

    TimeZone_Boundary on 2011-11-04 at 11:00:00 to CST                  

    TimeZone_Boundary on 2012-03-09 at 11:00:00 to CDT                  

    TimeZone_Boundary on 2012-11-02 at 11:00:00 to CST                  

    TimeZone_Boundary on 2013-03-08 at 11:00:00 to CDT                  

    TimeZone_Boundary on 2013-11-01 at 11:00:00 to CST    

 

 

Ed Zell
Illinois Mutual Life
(309) 636-0107              
  

  

 

________________________________

From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Frank M. Ramaekers
Sent: Friday, March 12, 2010 10:00 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Daylight Saving Time w/ VSE

 

This is the first time (in quite some time) that I've had a Daylight
Saving Time (Spring Forward).  Last year we did a Fall Backward by
shutting the system down for one hour.

 

So, here are my questions:

 

1)         VM time has to be done manually?   Has anyone done this via
VMUTIL (for example?

2)         Does anything need to be done to the z/VSEs (when springing
forward)?

3)         Will z/VSE pick up the time change when it's changed on VM?

4)         Are there special conditions for 2 and 3 above (specifically
SET CLOCK/ZONE/ZONEDEF/ZONEBDY settings)

 

 Frank M. Ramaekers Jr.

 

Systems Programmer

MCP, MCP+I, MCSE & RHCE

American Income Life Insurance Co.

Phone: (254)761-6649

1200 Wooded Acres Dr.

Fax: (254)741-5777

Waco, Texas  76701

 

 

_____________________________________________________ This message
contains information which is privileged and confidential and is solely
for the use of the intended recipient. If you are not the intended
recipient, be aware that any review, disclosure, copying, distribution,
or use of the contents of this message is strictly prohibited. If you
have received this in error, please destroy it immediately and notify us
at privacy...@ailife.com. 


.


CONFIDENTIALITY: This e-mail (including any attachments) may contain 
confidential, proprietary and privileged information, and unauthorized 
disclosure or use is prohibited.  If you receive this e-mail in error, notify 
the sender and delete this e-mail from your system.

Reply via email to