Tape Manager for z/VM

2010-06-07 Thread Mark Pace
Does anyone know where error messages for Tape Manager are documented? I've looked in the only 2 manuals I can find IBM Tape Manager for z/VM Installation Administration Guide V1R2http://publibz.boulder.ibm.com/epubs/pdf/c189344a.pdf http://publibz.boulder.ibm.com/epubs/pdf/c189344a.pdfIBM Tape

Re: Tape Manager for z/VM

2010-06-07 Thread Quay, Jonathan (IHG)
Its not documented, but it looks like it means you get to debug the socket connection between you and z/OS. From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf Of Mark Pace Sent: Monday, June 07, 2010 2:58 PM To:

Re: Tape Manager for z/VM

2010-06-07 Thread McKown, John
Can't find anything either. Does your z/VM system have IP connectivity to the z/OS system which is running the RMM Agent Started Task? John McKown Systems Engineer IV IT Administrative Services Group HealthMarkets(r) 9151 Boulevard 26 * N. Richland Hills * TX 76010 (817) 255-3225 phone *

Re: Tape Manager for z/VM

2010-06-07 Thread Mark Pace
Yep, I have NJE/TCPIP connect between these 2. The problem seems to be one side (z/OS wants a host name) the z/VM side wants IP addresses. I have 2 connections, 1 a public IP address going over the OSA, and a private address that goes over Hipersockets. I wanted to use the Hipersockets and put

MONDCSS segment update

2010-06-07 Thread Dean, David (I/S)
Is it safe to change MONDCSS sizes on running system, i.e., I won't run over memory being used somewhere else? David M. Dean Information Systems BlueCross BlueShield Tennnessee - Please see the following link for the BlueCross BlueShield of

Re: MONDCSS segment update

2010-06-07 Thread Edward M Martin
Hello David, You can do a Q NSS MAP to see if it will overlay anything you are going to use. Ed Martin Aultman Health Foundation 330-363-5050 ext 35050 From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf Of Dean, David (I/S) Sent: Monday, June 07, 2010 3:31

Re: Tape Manager for z/VM

2010-06-07 Thread McKown, John
Perhaps it is like the COBOL messages and codes. There is no need for a manual because the messages are so clear and complete that an explanation would be redundant. grin. John McKown Systems Engineer IV IT Administrative Services Group HealthMarkets(r) 9151 Boulevard 26 * N. Richland Hills

Re: MONDCSS segment update

2010-06-07 Thread Barton Robinson
Totally safe. Only users of the star monitor function will notice - so the monitor does need to stop and start. Dean, David (I/S) wrote: Is it safe to change MONDCSS sizes on running system, i.e., I won’t run over memory being used somewhere else? David M. Dean Information Systems BlueCross

Re: Tape Manager for z/VM

2010-06-07 Thread Mark Pace
Yes, these are all perfectly self-explanatory. :-D EUMTAP0010I RMM message 07 received from MARPACE. EUMTAP0288I RMM request 07 sent - awaiting reply. EUMTAP0260E Request 07 returned RC 12 - RMM command failed. EUMTAP0292I RMM command request 07 failed - RC 36. VMT021I -