: Re: RSCS CTCA between a first and second level system...
Sent by: The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
On Monday, 02/07/2011 at 11:53 EST, RPN01 nix.rob...@mayo.edu wrote:
The systems are polar and npolar.
DMTNCR916E Invalid NJE signon connection record received
I need to transfer some files between a first and second level system, and
tried to define an RSCS CTCA connection, but when I try to start the
connection, the see each other, but immediately shut down the link. The
second level connection gets the following messages:
DMTCMY700I Activating link
On Monday, 02/07/2011 at 11:15 EST, RPN01 nix.rob...@mayo.edu wrote:
DMTCMY700I Activating link NPOLAR NJE line=AA20 class=*
queueing=priority
DMTNET141I Line AA20 ready for connection to link NPOLAR
DMTNET142I Link NPOLAR line AA20 dataset ready
DMTNCR916E Invalid NJE signon connection
The systems are polar and npolar.
On 2/7/11 10:22 AM, Alan Altmark alan_altm...@us.ibm.com wrote:
On Monday, 02/07/2011 at 11:15 EST, RPN01 nix.rob...@mayo.edu wrote:
DMTCMY700I Activating link NPOLAR NJE line=AA20 class=*
queueing=priority
DMTNET141I Line AA20 ready for connection to link
On Monday, 02/07/2011 at 11:53 EST, RPN01 nix.rob...@mayo.edu wrote:
The systems are polar and npolar.
DMTNCR916E Invalid NJE signon connection record received
That message comes out because signon record contains
- A node id that doesn't match the local system's expectation of who is at
the
wrote on 02/07/2011
10:28:48 AM:
From: Alan Altmark/Endicott/IBM@IBMUS
To: IBMVM@LISTSERV.UARK.EDU
Date: 02/07/2011 10:30 AM
Subject: Re: RSCS CTCA between a first and second level system...
Sent by: The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
On Monday, 02/07/2011 at 11:53 EST
I need to transfer some files between a first and second level system, and
tried to define an RSCS CTCA connection, but when I try to start the
connection, the see each other, but immediately shut down the link. The
second level connection gets the following messages:
DMTCMY700I Activating link