Yordy,
I'll look into this when I get a chance, but that might not be until later in
the week (I am on travel at the moment).
B
--
Bruce Ravel --- [EMAIL PROTECTED]
National Institute of Standards and Technology
Synchrotron Methods Group at Brookhaven
Dear Yordy,
this error message actually occured because the crystallographic data in
the .cif file is somewhat ambigous. The space group is P 2/c (number
13), which is a monoclinic cell (with two different settings, as
additional complication: unique axis b or c).
Now, if you look in the .cif
Yordy, Bruce
Apparently Atoms doesn't like it that the beta angle in a monoclinic cell is 90
degrees. When I change the beta angle to 91 degrees or even 90.0001 (and
change nothing else), Atoms runs normally. It's interesting that although
Artemis says it has written a message nothing
Hi,
This is my fault... and I apologize for the sloppiness and for being
late in fixing this. I've been mixing 'development/testing' and
'production' versions, and haven't been very good at keeping them
cleanly separated. I think I have this mostly under control now,
but I will have to
Hi Folks,
I've uploaded source kits for Ifeffit 1.2.11c to the cars.uchicago.edu
and sourceforge.net download sites.
I have a Windows dll made for this bug fix version. If anyone is
interested, this is currently at
http://cars.uchicago.edu/~ifeffit/updates/011/bin/ifeffit_12.dll
This should
Debian packages have been uploaded to unstable and I am in the process of
building Ubuntu packages for my repository. i expect that they will be up
tonight.
carlo
On Mon, 17 Nov 2008, Matt Newville wrote:
Hi Folks,
I've uploaded source kits for Ifeffit 1.2.11c to the cars.uchicago.edu
Thanks, Carlo!
--Matt
On Mon, Nov 17, 2008 at 8:03 PM, Carlo Segre [EMAIL PROTECTED] wrote:
Debian packages have been uploaded to unstable and I am in the process of
building Ubuntu packages for my repository. i expect that they will be up
tonight.
carlo
On Mon, 17 Nov 2008, Matt