Hi All
There has been much discussion of this at the recent Q2XAFS meeting.
Proceedings are I believe being reviewed at the moment.
>From I think some consensus of those attending, the most critical and most
portable data was [mu/rho] versus E, with uncertainties; or mu versus E.
Secondary data s
On Monday, May 07, 2012 07:57:12 PM Luanga Nchari wrote:
> Hi folks,
> Does anybody know how to plot data for Gaussian and arctangent step peaks
> (from Athena) in Excel. I can't find the data after peak fitting. I've also
> searched in the Ifeffit mailing list archive. Cheers,
> Luanga
>From t
Hi folks,
Does anybody know how to plot data for Gaussian and arctangent step peaks (from
Athena) in Excel. I can't find the data after peak fitting. I've also searched
in the Ifeffit mailing list archive.
Cheers,
Luanga ___
Ifeffit mailing list
Ifeff
On Monday, May 07, 2012 04:10:35 PM mattie.p...@huskers.unl.edu wrote:
> Hello Everyone,
>
> I am in the process of fitting XAFS data for a paper and I was wondering
> what type of information should should be included. I remember coming
> across a website that had this information on it awhile a
Hello Everyone,
I am in the process of fitting XAFS data for a paper and I was wondering what
type of information should should be included. I remember coming across a
website that had this information on it awhile ago but I can't seem to find my
way back. We would like to publish a qualitati
On May 6, 2012 11:01 PM, "JeongEunSuk" wrote:
>
> Hello
> I measured temperature-dependent EXAFS at Pt L3 edge with Pt
nanoparticles in room and high temperature(400 C). I have some questions
about thermal vibration in EXAFS fit. I read that third and fourth
culmulants related with phase and ampli