On Wed, 2016-03-16 at 11:49 +0200, Jani Nikula wrote:
> On Wed, 16 Mar 2016, Mika Kahola wrote:
> > [ text/plain ]
> > It was noticed on bug #94087 that module parameter
> > i915.edp_vswing=2 that should override the VBT setting
> > to use default voltage swing (400 mV) was not applied
> > for Bro
On Wed, 16 Mar 2016, Mika Kahola wrote:
> [ text/plain ]
> It was noticed on bug #94087 that module parameter
> i915.edp_vswing=2 that should override the VBT setting
> to use default voltage swing (400 mV) was not applied
> for Broadwell.
>
> This patch provides a fix for this by checking if defa
It was noticed on bug #94087 that module parameter
i915.edp_vswing=2 that should override the VBT setting
to use default voltage swing (400 mV) was not applied
for Broadwell.
This patch provides a fix for this by checking if default
i.e. higher voltage swing is requested to be used and
applies the